All Products
Contact Person :
Owen Zhang
Phone Number :
+86 18560013985
WhatsApp :
+8618560013985
Gelbo Flex Durability Testing Instrument Flex Durability Tester For Flexible Barrier Material Vacuum Pack Bags Qaulity
Flex Frequency: | 45 /minute |
---|---|
Flex Angle: | 440° (90 Mm) Or 400° (80 Mm) |
Capacity: | 2.5 N.m |
ASTM F392 Tester Flex Durability Testing Machine Barrier Film Quality Testing Equipment Food Packaging Gelbo Flex Tester
Flex Frequency: | 45 /minute |
---|---|
Flex Angle: | 440° (90 Mm) Or 400° (80 Mm) |
Capacity: | 2.5 N.m |
Food Pack Bag Hot Seal Strength Testing Equipment Thermoplastic Film Heat Sealability Testing Machine Hot Tack Strength
Sealing Temp.: | Ambient~250℃ |
---|---|
Temp Accuracy: | ±0.2℃ |
Dwell Time: | 0.1~9999s(Hot Tack ) |
ASTM F2029 Heat Seal Packaging Testers ASTM F1921 Hot Tack Strength Testing Instruments Heat Seal Laboratory Tester
Sealing Temp.: | Ambient~250℃ |
---|---|
Temp Accuracy: | ±0.2℃ |
Dwell Time: | 0.1~9999s(Hot Tack ) |
Packaging heat sealing Surfaces tensile strength testing equipment ASTM F1921 Polymer film hot tack testing instrument
Sealing Temp.: | Ambient~250℃ |
---|---|
Temp Accuracy: | ±0.2℃ |
Dwell Time: | 0.1~9999s(Hot Tack ) |
Thermoplastic Hot Seal Strength Testing Instruments ASTM F1921 Hot Tack Strength Tester Thermoplastic Heat Seal Tensile
Sealing Temp.: | Ambient~250℃ |
---|---|
Temp Accuracy: | ±0.2℃ |
Dwell Time: | 0.1~9999s(Hot Tack ) |
Hot Tack Strength Tester Heat Seal Strength Testing Machine ASTM F921 Hot Seal Tester Plastic Packaging Physical Tester
Sealing Temp.: | Ambient~250℃ |
---|---|
Temp Accuracy: | ±0.2℃ |
Dwell Time: | 0.1~9999s(Hot Tack ) |
Falling Dart Impact Tester For Plastic Film Paper Package Impact Tester By Dart Drop Method ASTM D1709 Impact Tester
Test Method: | Method A Or Method B (optional) |
---|---|
Test Range: | Method A: 50~2000g/Method B: 300~2000g |
Dart Diameter: | Method A: 38±1mm/Method B: 50±1mm |
Falling Dart Impact Tester For Bopp Bag ASTM D1709 Packaging Testers Hmi Touch Screen Free Fall Drop Testing Equipment
Test Method: | Method A Or Method B (optional) |
---|---|
Test Range: | Method A: 50~2000g/Method B: 300~2000g |
Dart Diameter: | Method A: 38±1mm/Method B: 50±1mm |
ASTM D1709 Plastic Film Impact Resistance Tester Drop Test Machine For Packaging Material Hot Sale Free Fall Drop Tester
Test Method: | Method A Or Method B (optional) |
---|---|
Test Range: | Method A: 50~2000g/Method B: 300~2000g |
Dart Diameter: | Method A: 38±1mm/Method B: 50±1mm |